صور الصفحة
PDF
النشر الإلكتروني
[blocks in formation]

8 430.13 Effluent limitations guidelines

representing the degree of effluent reduction attainable by the application of the best conventional pollut

ant control technology (BCT). Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in 40 CFR 401.16) in $ 430.12 of this subpart for the best practicable control technology currently available (BPT).

8 430.14 Effluent limitations

representing the degree of effluent reduction attainable by the application of the best available technology economically achievable

(BAT). Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart where chlorophenolic-containing biocides are used must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT). Non-continuous dischargers shall not be subject to the maximum day mass limitations in kg/kkg (lb/1000 lb) but shall be subject to concentration limitations. Concentration limitations are only applicable to non-continuous dischargers. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides:

[blocks in formation]

source

$ 430.15 New

performance standards (NSPS). Any new source subject to this subpart must achieve the following new

source performance standards (NSPS), except that non-continuous dischargers shall not be subject to the maximum day and average of 30 consecutive days effluent limitations for BOD5 and TSS,

but shall be subject to annual average used shall be subject to effluent limitations. Also, for non-con- pentachlorophenol and trichlorophenol tinuous dischargers, concentration lim- limitations. Permittees not using itations (mg/l) shall apply, where pro- chlorophenolic-containing biocides vided. Concentration limitations will

must certify to the permit-issuing auonly apply to non-continuous dis

thority that they are not using these chargers. Only facilities where

biocides: chlorophenolic-containing biocides are

SUBPART A

(NSPS]

[blocks in formation]

$430.16 Pretreatment standards for pretreatment standards for existing existing sources (PSES).

sources (PSES) if it uses Except as provided in 40 CFR 403.7 chlorophenolic-containing biocides. and 403.13, any existing source subject

Permittees not using chlorophenolicto this subpart that introduces pollut- containing biocides must certify to the ants into a publicly owned treatment permit-issuing authority that they are works must: comply with 40 CFR part not using these biocides. PSES must be 403; and achieve the following attained on or before July 1, 1984:

SUBPART A

(PSES]

Maximum for any 1 day

Pollutant or pollutant property

Milligrams/liter (mg/l)

Kg/kkg (or pounds per 1,000 lb) of product a

Pentachlorophenol

(0.011)(55.1)/y

0.0025 Trichlorophenol

(0.082)(55.1)/y

0.019 y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

8430.17 Pretreatment standards for

new sources (PSNS). Except as provided in 40 CFR 403.7, any new source subject to this subpart

that introduces pollutants into a publicly owned treatment works must; comply with 40 CFR part 403; and achieve the following pretreatment

208-169 D-5

uses

standards for new sources (PSNS) if it must certify to the permit-issuing au

chlorophenolic-containing thority that they are not using these biocides. Permittees not using biocides: chlorophenolic-containing biocides

SUBPART A

(PSNS]

Maximum for any 1 day

Pollutant or pollutant property

Milligrams/liter (mg/l)

Kgkkg (or pounds per 1,000 lb) of product

Pentachlorophenol

(0.012)(50.7)/y

0.0025 Trichlorophenol

(0.089)(50.7)/y

0.019 y = wastewater discharged in kgal per ton of product.

a The following equivalent mass limitations are provided as guidance in cases when POTWs find it necessary to impose mass effluent limitations.

Subpart B-Bleached Papergrade

Kraft and Soda Subcategory $ 430.20 Applicability; description of

the bleached papergrade kraft and

soda subcategory. The provisions of this subpart apply to discharges resulting from: The production of market pulp at bleached kraft mills; the integrated production of paperboard, coarse paper, and tissue paper at bleached kraft mills; the integrated production of pulp and fine papers at bleached kraft mills; and the integrated production of pulp and paper at soda mills.

the permitting authority as long as the mill signs the correspondence in accordance with 40 CFR 122.22.

(d) Existing effluent quality means the level at which the pollutants identified in $430.24(a)(1) are present in the effluent of a mill "enrolled" in the “Voluntary Advanced Technology Incentives Program."

(e) Kappa number is a measure of the lignin content in unbleached pulp, determined after pulping and prior to bleaching.

(f) Voluntary Advanced Technology Incentives Program is the program established under $ 430.24(b) (for existing direct dischargers) and § 430.25(c) (for new direct dischargers) whereby participating mills agree to accept enforceable effluent limitations and conditions in their NPDES permits that are more stringent than the “baseline BAT limitations or NSPS” that would otherwise apply,

exchange for regulatory and enforcement-related rewards and incentives.

in

$ 430.21 Specialized definitions.

(a) The general definitions, abbreviations, and methods of analysis set forth in 40 CFR part 401 and $ 430.01 of this part apply to this subpart.

(b) Baseline BAT limitations or NSPS means the BAT limitations specified in § 430.24(a) (1) or (2), as applicable, and the NSPS specified in $430.25(b) (1) or (2), as applicable, that apply to any direct discharger that is not "enrolled": in the “Voluntary Advanced Technology Incentives Program.”

(c) Enroll means to notify the permitting authority that a mill intends to participate in the “Voluntary Advanced Technology Incentives Program.” A mill can enroll by indicating its intention to participate in the program either as part of its application for a National Pollutant Discharge Elimination System (NPDES) permit, or through separate correspondence to

$ 430.22 Effluent limitations rep

resenting the degree of effluent reduction attainable by the applica. tion of the best practicable control technology currently available

(BPT). (a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

[blocks in formation]

SUBPART B [BPT effluent limitations for bleached kraft facilities where paperboard, coarse paper, and tissue paper are produced)

[blocks in formation]

SUBPART B
(BPT effluent limitations for bleached kraft facilities where pulp and fine papers are produced]

[blocks in formation]

(b) The following limitations estab- limitations are in addition to the limilish the quantity or quality of pollut- tations set forth in paragraph (a) of ants or pollutant properties, controlled this section and shall be calculated by this section, resulting from the use using the proportion of the mill's total of wet barking operations, which may production due to use of logs which are be discharged by a point source subject subject to such operations: to the provisions of this subpart. These

SUBPART B
(BPT effluent limitations for bleached kraft facilities where market pulp is produced]

[blocks in formation]

SUBPART B (BPT effluent limitations for bleached kraft facilities where paperboard, coarse paper, and tissue paper are produced]

[blocks in formation]

SUBPART B
(BPT effluent limitations for bleached kraft facilities where pulp and fine papers are produced)

[blocks in formation]
« السابقةمتابعة »